K₂EDTA Versus K₃EDTA Stability in Yemeni Laboratories: Toward Climate-Adapted Protocols for Resource-Limited Settings

Clicks: 1
ID: 311562
2025
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #208 of 254 articles by views in Yemen Journal of Medicine

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 254 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: Preanalytical variability due to anticoagulant choice remains inadequately characterized in resource-limited tropical settings like Yemen, where environmental stressors exacerbate challenges. This study aimed to compare the stability and cost-effectiveness of K₂EDTA and K₃EDTA anticoagulants for complete blood count testing under simulated Yemeni conditions. Methods: Prospective study of 100 healthy adult male volunteers in Ad’Dla Governorate, Yemen (January–March 2025). Paired samples in K₂EDTA/K₃EDTA tubes were analyzed at baseline (T0) and after 6-hour storage at 22 ± 2°C (T6). Statistical analysis included Bonferroni-corrected repeated-measures ANOVA and paired t-tests. Results: Fresh samples showed high inter-anticoagulant concordance (ICC > 0.90). After 6-hour storage, K₂EDTA exhibited significant Mean Corpuscular Volume (MCV) reduction (Δ = −2.33 fL, p < 0.001; Cohen’s d = 0.42), while K₃EDTA showed greater Red Blood Cell (RBC) instability (Δ = −0.16 × 10¹²/L, p = 0.008). An observed bidirectional Red Cell Distribution Width – Standard Deviation (RDW-SD) pattern emerged: K₂EDTA increased values (+1.71%) while K₃EDTA decreased them (−2.20%, both p < 0.01). K₃EDTA offered 4.7% direct cost savings per test but incurred higher slide-review costs due to 8% platelet clumping. Conclusions: K₂EDTA demonstrates superior stability for delayed processing (> 2 hours), while K₃EDTA is preferable for immediate analysis. These findings provide preliminary guidance for hematology testing in Yemeni laboratories and similar tropical settings, pending validation in diverse populations and extreme conditions.
Reference Key
ali2025kedta Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Naif Taleb Ali
Journal Yemen Journal of Medicine
Year 2025
DOI
10.63475/yjm.v4i2.0150
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.