Revealing the Elemental Distribution within Latent Fingermarks Using Synchrotron Sourced X-ray Fluorescence Microscopy.
Clicks: 254
ID: 31023
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
74.3
/100
254 views
204 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #55 of 194 articles by views in Analytical chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 194 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Fingermarks are an important form of crime-scene trace evidence; however, their usefulness may be hampered by a variation in response or a lack of robustness in detection methods. Understanding the chemical composition and distribution within fingermarks may help explain variation in latent fingermark detection with existing methods and identify new strategies to increase detection capabilities. The majority of research in the literature describes investigation of organic components of fingermark residue, leaving the elemental distribution less well understood. The relative scarcity of information regarding the elemental distribution within fingermarks is in part due to previous unavailability of direct, micron resolution elemental mapping techniques. This capability is now provided at third generation synchrotron light sources, where X-ray fluorescence microscopy (XFM) provides micron or submicron spatial resolution and direct detection with sub-μM detection limits. XFM has been applied in this study to reveal the distribution of inorganic components within fingermark residue, including endogenous trace metals (Fe, Cu, Zn), diffusible ions (Cl, K, Ca), and exogeneous metals (Ni, Ti, Bi). This study incorporated a multimodal approach using XFM and infrared microspectroscopy analyses to demonstrate colocalization of endogenous metals within the hydrophilic organic components of fingermark residue. Additional experiments were then undertaken to investigate how sources of exogenous metals (e.g., coins and cosmetics) may be transferred to, and distributed within, latent fingermarks. Lastly, this study reports a preliminary assessment of how environmental factors such as exposure to aqueous environments may affect elemental distribution within fingermarks. Taken together, the results of this study advance our current understanding of fingermark composition and its spatial distribution of chemical components and may help explain detection variation observed during detection of fingermarks using standard forensic protocols.
| Reference Key |
boseley2019revealinganalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Boseley, Rhiannon E;Dorakumbura, Buddhika N;Howard, Daryl L;de Jonge, Martin D;Tobin, Mark J;Vongsvivut, Jitraporn;Ho, Tracey T M;van Bronswijk, Wilhelm;Hackett, Mark J;Lewis, Simon W; |
| Journal | Analytical chemistry |
| Year | 2019 |
| DOI |
10.1021/acs.analchem.9b01843
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.