A mathematical framework for peristaltic flow analysis of non-Newtonian Sisko fluid in an undulating porous curved channel with heat and mass transfer effects.

Clicks: 241
ID: 30852
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #39 of 70 articles by views in computer methods and programs in biomedicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Peristaltic is one of the most frequently occurring phenomenon in biological systems. These systems of the human body (especially digestive, reproductive, respiratory, renal system) generally involve effects of curvature, porosity, rheology and heat transfer. Thus, in the present investigation we integrate heat transfer phenomenon with Sisko fluid flowing through porous medium bounded within curved wavy walls. The theoretical analysis presented under long wavelength approximation serves as a model for the creeping non-isothermal flow of blood through a diseased segment of the artery due to vasomotion (peristaltic motion) in the artery.The highly nonlinear ordinary differential equation with appropriate boundary conditions is solved using a well-tested implicit finite difference scheme. A comparison of velocity profile for Newtonian, power-law and Sisko fluids is also presented.The Sisko model predict higher values of velocity in the central core region than power-law and Newtonian model. The size of circulating bolus of fluid reduces with increasing permeability parameter. The symmetry in velocity and streamlines pattern is observed when dimensionless radius of curvature becomes very large.
Reference Key
asghar2019acomputer Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Asghar, Zeeshan;Ali, Nasir;Ahmed, Raheel;Waqas, Muhammad;Khan, Waqar Azeem;
Journal computer methods and programs in biomedicine
Year 2019
DOI
S0169-2607(19)31143-5
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.