Dental cone beam ct and its justified use in oral health care
Clicks: 317
ID: 30747
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
75.3
/100
317 views
226 readers
Trending
AI Quality Assessment
Not analyzed
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
While dental 2D radiology is still the most frequent diagnostic tool, the inherent nature of jaws and teeth might surely benefit from 3D diagnosis. Nowadays, dental cone beam computed tomography may offer high quality images at low radiation doses and costs. Yet, effective dose ranges of CBCT machines may easily vary from 10-1200 micro - sievert, being an equivalent of 2 to 240 dental panoramic radiographs. The same holds true for diagnostic image quality, which exhibits a huge variation amongst machines and parameter settings. For segmentation accuracy, lower limits of accuracy are around 200 micrometer, yet again, larger inaccuracies may apply. For linear accuracies, values below 500 micrometer are feasible, with some machines and CBCT parameter settings allowing linear accuracies of up to 200 micrometer. Apart from the radiodiagnostic possibilities, dental cone beam CT may offer a vast therapeutic potential, including possibilities for surgical guidance and further treatment via CAD/CAM solutions for crown and bridgework on teeth or implants. In conclusion, dental CBCT imaging could be justified when dealing with specific indications including jaw bone and maxillofacial surgery, endodontic retreatment, traumata, jaw bone lesions and TMJ pathology. Yet, guidelines for CBCT optimisation and justification are mandatory, especially when used for pediatric indications.
| Reference Key |
jacobs2011dentaljournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Jacobs, R; |
| Journal | journal of the belgian society of radiology |
| Year | 2011 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.