Volumetry of Hippocampus and Amygdala with High-resolution MRI and Three-dimensional Analysis Software: Minimizing the Discrepancies between Laboratories
Clicks: 1
ID: 307194
2000
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #106 of 107 articles by views in cerebral cortex (new york, ny : 1991)
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Within the medial temporal lobe, both the hippocampus and amygdala are frequently targeted by researchers and clinicians for volumetric analysis based on magnetic resonance imaging (MRI). However, different data acquisition techniques, analysis software and anatomical boundaries have in the past made it difficult to compare results of MRI studies from different laboratories. In order to reduce these differences, a segmentation protocol was established with 40 healthy normal control subjects recently scanned in our laboratory. Data acquisition was performed with a three-dimensional gradient echo technique, and scans were corrected for non-uniformity and registered into standard stereotaxic space prior to segmentation. Volumetric analysis was performed manually using three-dimensional software that allows simultaneous analysis of sagittal, coronal and horizontal images. Intra- and inter-rater coefficients yielded correlation coefficients comparable with other protocols. The hippocampal volume was larger in the right hemisphere (3324 versus 3208 mm3), while no interhemispheric differences for the amygdala (1154 versus 1160 mm3) could be observed. Most importantly, results from recent segmentation protocols for hippocampus and amygdala seem to approach each other with regard to mean volumes and interhemispheric differences. This indicates that the advances in scanning technique, volume preparation and segmentation protocols allow a more precise definition of medial temporal lobe structures with MRI, and that results for mean volumes for hippocampus and amygdala from different laboratories will eventually become comparable.
| Reference Key |
openalex_W2155492919
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Jens C. Pruessner |
| Journal | cerebral cortex (new york, ny : 1991) |
| Year | 2000 |
| DOI |
10.1093/cercor/10.4.433
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.