A double-diffusive interface tank for dynamic-response studies

Clicks: 2
ID: 305747
2005
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #1,356 of 1,397 articles by views in journal of marine research

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,397 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A large tank capable of long-term maintenance of a sharp temperature-salinity interface has been developed and applied to measurements of the dynamical response of oceanographic sensors.A two-layer salt-stratified system is heated from below and cooled from above to provide two convectively mixed layers with a thin double-diffusive interface separating them.A temperature jump exceeding 10°C can be maintained over 1-2 cm (a vertical temperature gradient of order 10 3 °C/m) for several weeks.A variable speed-lowering system allows testing of the dynamic response of conductivity and temperature sensors in full-size oceanographic instruments.An acoustic echo sounder and shadowgraph system provide nondisruptive monitoring of the interface and layer microstructure.Tests of several sensor systems show how data from the facility is used to determine sensor response times using several fitting techniques and the speed dependence of thermometer time constants is illustrated.The linearity of the conductivity-temperature relationship across the interface is proposed as a figure of merit for design of lag-correction filters to accurately match temperature and conductivity sensors for the computation of salinity.The effects of finite interface thickness, slow sensor sampling rates and the thermal mass of the conductivity cell are treated.Sensor response characterization is especially important for autonomous instruments where data processing and compression must be performed in-situ, but is also helpful in the development of new sensors and in assuring accurate salinity records from traditional wire-lowered and towed systems.
Reference Key
openalex_W2035994591 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Raymond W. Schmitt, Robert C. Millard, John M. Toole, W. David Wellwood
Journal journal of marine research
Year 2005
DOI
10.1357/0022240053693842
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.