Fabrication of paper-based microfluidic device by recycling foamed plastic and the application for multiplexed measurement of biomarkers.
Clicks: 491
ID: 3047
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
72.6
/100
491 views
354 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #5 of 116 articles by views in spectrochimica acta part a, molecular and biomolecular spectroscopy
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Microfluidic paper-based analytical devices (μPADs) are emerging as effective analytical platforms for point-of-care assays in resource-limited areas. Simple and cost-effective fabrication method still remains challenging on μPADs. A simple and cost-effective method for fabricating paper-based devices was presented in this work by using of dipping strategy with the recycled polystyrene in chloroform as the hydrophobic reagent. Adhesive tape was employed as mask to transfer the hydrophilic channel pattern to the paper substrate. With the single-sided adhesive tape stuck on the hydrophilic parts of the paper surface, the paper-based device was immersed in chloroform solution with dissolving recycling polystyrene for several seconds. Then the hydrophilic pattern can be achieved and all the other parts on the paper surface were hydrophobic. The adhesive tape was torn off from the hydrophilic parts. The highest contact angle value of 114° of the hydrophobic part was acquired with this simple fabrication method. By using of the sandwich-type immunoreactions and luminol-HOp-iodophenol (PIP) chemiluminescence(CL) system, three cancer biomarkers were simultaneously detected in human serum samples on μPADs with the linear range of 0.05-80.0 ng·mL for carcinoembryonic antigen (CEA), 5.0-80.0 ng·mL for alpha-fetal protein (AFP) and 1.0-50.0 ng·mL for prostate-specific antigen (PSA). The fabricating strategy with recycling polystyrene and adhesive tape provides a versatile platform for prototyping of μPADs in both developed and resource constrained region.
| Reference Key |
guo2019fabricationspectrochimica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Guo, Xiaoyan;Guo, Yumei;Liu, Wei;Chen, Ying;Chu, Weiru; |
| Journal | spectrochimica acta part a, molecular and biomolecular spectroscopy |
| Year | 2019 |
| DOI |
S1386-1425(19)30731-0
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.