A Microassay for 1,25-Dihydroxyvitamin D Not requiring High Performance Liquid Chromatography: Application to Clinical Studies*
Clicks: 3
ID: 303771
1984
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.6
/100
3 views
2 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #175 of 362 articles by views in the journal of clinical endocrinology & metabolism
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 362 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This report describes a microassay for 1,25––dihydroxyvitamin D [1,25–(OH)2D] in plasma which does not require high performance liquid chromatography. The assay involves rapid extraction and preliminary purification on a C-18 Sep-Pak cartridge, followed by final purification on a silica Sep-Pak using hexane-isopropanol. Quantitation of 1,25-(OH)2D is achieved using a nonequilibrium assay employing 1,25-(OH)2D receptor from calf thymus. The method is sensitive to 1.5 pg/tube, with B50 occurring at 9 pg/tube and a useful assay range of 1.5–40 pg/tube. The intra- and interassay coefficients of variation are 6.5% and 11.5%, respectively, and the method is linear over a wide range of sample dilutions. In addition, this assay measures both 1,25-(OH)2D2 and 1,25-(OH)2D3 with equal affinity. The importance of using an assay with equal affinity for 1,25-(OH)2D2 and 1,25-(OH)2D3 is demonstrated by the findings that 25-hydroxyvitamin D2 (250HD2) constituted 38.9% of the total 25-OHD found in clinical samples (12.6 ± 0.7 ng/ml 25-OHD2 vs. 20.1 ± 0.5 ng/ml 25-OHD3; n = 807). Results of this new assay have been compared to those of the assay of Horst et al. (21), which employs Sephadex LH-20 and high performance liquid chromatography sample purification. The correlation coefficient was r2 = 0.96, and the slope was 1.05. Using this new assay, plasma 1,25-(OH)2D concentrations were as follows: normal adults, 37.4 ± 2.2 pg/ml (n = 22); chronic renal failure, 10.6 ± 1.5 pg/ml (n = 7); anephrics, undetectable (n = 10); infant cord blood, 22.9 ± 4.4 pg/ml (n = 7); and hyperparathyroidism, 68.9 ± 5.0 pg/ml (n = 13). This assay should be particularly useful in pediatric or other studies in which sample size is limited.
| Reference Key |
openalex_W2167999248
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Timothy A. Reinhardt, Ronald L. Horst, John W. Orf, Bruce W. Hollis |
| Journal | the journal of clinical endocrinology & metabolism |
| Year | 1984 |
| DOI |
10.1210/jcem-58-1-91
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.