A Microassay for 1,25-Dihydroxyvitamin D Not requiring High Performance Liquid Chromatography: Application to Clinical Studies*

Clicks: 3
ID: 303771
1984
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #175 of 362 articles by views in the journal of clinical endocrinology & metabolism

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 362 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This report describes a microassay for 1,25––dihydroxyvitamin D [1,25–(OH)2D] in plasma which does not require high performance liquid chromatography. The assay involves rapid extraction and preliminary purification on a C-18 Sep-Pak cartridge, followed by final purification on a silica Sep-Pak using hexane-isopropanol. Quantitation of 1,25-(OH)2D is achieved using a nonequilibrium assay employing 1,25-(OH)2D receptor from calf thymus. The method is sensitive to 1.5 pg/tube, with B50 occurring at 9 pg/tube and a useful assay range of 1.5–40 pg/tube. The intra- and interassay coefficients of variation are 6.5% and 11.5%, respectively, and the method is linear over a wide range of sample dilutions. In addition, this assay measures both 1,25-(OH)2D2 and 1,25-(OH)2D3 with equal affinity. The importance of using an assay with equal affinity for 1,25-(OH)2D2 and 1,25-(OH)2D3 is demonstrated by the findings that 25-hydroxyvitamin D2 (250HD2) constituted 38.9% of the total 25-OHD found in clinical samples (12.6 ± 0.7 ng/ml 25-OHD2 vs. 20.1 ± 0.5 ng/ml 25-OHD3; n = 807). Results of this new assay have been compared to those of the assay of Horst et al. (21), which employs Sephadex LH-20 and high performance liquid chromatography sample purification. The correlation coefficient was r2 = 0.96, and the slope was 1.05. Using this new assay, plasma 1,25-(OH)2D concentrations were as follows: normal adults, 37.4 ± 2.2 pg/ml (n = 22); chronic renal failure, 10.6 ± 1.5 pg/ml (n = 7); anephrics, undetectable (n = 10); infant cord blood, 22.9 ± 4.4 pg/ml (n = 7); and hyperparathyroidism, 68.9 ± 5.0 pg/ml (n = 13). This assay should be particularly useful in pediatric or other studies in which sample size is limited.
Reference Key
openalex_W2167999248 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Timothy A. Reinhardt, Ronald L. Horst, John W. Orf, Bruce W. Hollis
Journal the journal of clinical endocrinology & metabolism
Year 1984
DOI
10.1210/jcem-58-1-91
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.