Improvement of cell counting method for Neubauer counting chamber.
Clicks: 370
ID: 30307
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
74.7
/100
370 views
244 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #7 of 13 articles by views in journal of clinical laboratory analysis
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
We compared the cell counting accuracy of the conventional method and the improved method by using Neubauer counting chamber.In the improved method, all the border cells were counted and then divided by two; while, in the conventional method, only border cells on the two boundaries (top and left) were counted.About 55.814% of the samples showed more accurate results by improved counting method, about 38.372% had more accurate results by conventional counting method, and about 5.814% were counted with similar counting error by both methods. The improved method had significantly smaller counting error than conventional method (P < .05). The distribution ratio of the border cells was an independent factor for counting accuracy (P < .05).Together, the improved counting method can reduce the counting error of the Neubauer counting chamber to some extent, assess the distributing uniformity of border cells, and help to eliminate the samples with large differences in distribution.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (95 words).
Try re-searching for a better abstract.
| Reference Key |
zhang2019improvementjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhang, Minghao;Gu, Lingui;Zheng, Peihua;Chen, Zhixin;Dou, Xinqi;Qin, Qizhong;Cai, Xiaozhong; |
| Journal | journal of clinical laboratory analysis |
| Year | 2019 |
| DOI |
10.1002/jcla.23024
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.