Structure of Dietary Measurement Error: Results of the OPEN Biomarker Study

Clicks: 1
ID: 302899
2003
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #220 of 305 articles by views in american journal of epidemiology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 305 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Multiple-day food records or 24-hour dietary recalls (24HRs) are commonly used as "reference" instruments to calibrate food frequency questionnaires (FFQs) and to adjust findings from nutritional epidemiologic studies for measurement error. Correct adjustment requires that the errors in the adopted reference instrument be independent of those in the FFQ and of true intake. The authors report data from the Observing Protein and Energy Nutrition (OPEN) Study, conducted from September 1999 to March 2000, in which valid reference biomarkers for energy (doubly labeled water) and protein (urinary nitrogen), together with a FFQ and 24HR, were observed in 484 healthy volunteers from Montgomery County, Maryland. Accounting for the reference biomarkers, the data suggest that the FFQ leads to severe attenuation in estimated disease relative risks for absolute protein or energy intake (a true relative risk of 2 would appear as 1.1 or smaller). For protein adjusted for energy intake by using either nutrient density or nutrient residuals, the attenuation is less severe (a relative risk of 2 would appear as approximately 1.3), lending weight to the use of energy adjustment. Using the 24HR as a reference instrument can seriously underestimate true attenuation (up to 60% for energy-adjusted protein). Results suggest that the interpretation of findings from FFQ-based epidemiologic studies of diet-disease associations needs to be reevaluated.
Reference Key
openalex_W2125277071 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Victor Kipnis
Journal american journal of epidemiology
Year 2003
DOI
10.1093/aje/kwg091
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.