An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man
Clicks: 3
ID: 301744
1993
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Star Article
0.6
/100
3 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
StarRanked #64 of 310 articles by views in european heart journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 310 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Amplification of the pressure pulse between central and peripheral arteries renders pressure values in the upper limb an inaccurate measure of ascending aortic (AA) pressure. Accuracy could be improved by allowance for such amplification. Transfer functions (TF) for pressures between AA and brachial artery (BA): (BATF) and between AA and radial artery (RA): (RATF) were derived from high-fidelity pressure recordings obtained at cardiac catheterization in 14 patients under control conditions, and after sublingual nitroglycerine 0.3 mg. There was no significant difference in BATF under control conditions and with nitroglycerine; hence results were pooled. Control and nitroglycerine results were also pooled to obtain a single RATF. BATF and RATF moduli peaked at 5 Hz and 4 Hz, reaching 2.5 and 2.8 times the value at zero frequency respectively. Frequency-dependent changes in modulus and phase of BATF and RATF were attributable to wave travel and reflection in the upper limb. BATF and RATF were compared to published transfer functions and those derived from analysis of aortic and brachial or radial pressure waves in previous publications. Results were similar. Our BATF and RATF were used to synthesize AA pressure waves from published peripheral pulses. Correspondence was close, especially for systolic pressure which d by 2.4 ± 1.0 (mean ± SEM) mmHg, whereas recorded systolic pressure differed by 20.4 ± 2.6 (mean ± SEM) mmHg between central and peripheral sites. Results indicate that in adult humans a single generalized TF can be used with acceptable accuracy to determine central from peripheral pressure under different conditions. While this process is capable of refinement, it represents an advance on the present practice of assuming that central and peripheral pressures are identical.
| Reference Key |
openalex_W2067833505
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Mustafa Karamanoglu, Michael F. O’Rourke, Alberto Avolio, Raymond P. Kelly |
| Journal | european heart journal |
| Year | 1993 |
| DOI |
10.1093/eurheartj/14.2.160
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.