Walking on a Vertically Oscillating Treadmill: Phase Synchronization and Gait Kinematics.
Clicks: 286
ID: 30123
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
67.9
/100
286 views
235 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #998 of 2,056 articles by views in PloS one
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 2,056 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Sensory motor synchronization can be used to alter gait behavior. This type of therapy may be useful in a rehabilitative setting, though several questions remain regarding the most effective way to promote and sustain synchronization. The purpose of this study was to describe a new technique for using synchronization to influence a person's gait and to compare walking behavior under this paradigm with that of side by side walking. Thirty one subjects walked on a motorized treadmill that was placed on a platform that oscillated vertically at various frequencies and amplitudes. Synchronization with the platform and stride kinematics were recorded during these walking trials and compared with previously reported data from side by side walking. The results indicated that vertical oscillation of the treadmill surface at frequencies that matched subjects preferred stride or step frequency resulted in greater unintentional synchronization when compared with side by side walking data (up to 78.6±8.3% of the trial vs 59.2±17.4%). While intermittent phase locking was observed in all cases, periods of synchronization occurred more frequently and lasted longer while walking on the oscillating treadmill (mean length of periods of phase locking 11.85 steps vs 5.18 steps). Further, stride length, height and duration were altered by changing the frequency of treadmill oscillation. These results suggest that synchronization to a haptic signal may hold implications for use in a clinical setting.
| Reference Key |
nessler2017walkingplos
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Nessler, Jeff A;Heredia, Severne;Bélair, Jacques;Milton, John; |
| Journal | PloS one |
| Year | 2017 |
| DOI |
10.1371/journal.pone.0169924
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.