Generative Healing: AI-Driven Reconstruction of Damaged Medical Images for Low-Infrastructure Healthcare

Clicks: 48
ID: 295240
2025
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #10 of 15 articles by views in International Journal of Health Sciences and Engineering

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Medical imaging plays a pivotal role in clinical diagnostics, yet in many resource-limited hospitals and rural healthcare centers, the acquisition and preservation of high-quality CT and MRI scans are often compromised due to hardware degradation, motion artifacts, transmission noise, and incomplete data capture. These issues severely impact diagnostic accuracy and limit timely medical intervention. In response, this paper presents a robust Generative AI-based reconstruction framework that virtually restores degraded or partially corrupted medical images without requiring additional scans or expensive infrastructure upgrades. The proposed system integrates a Variational Autoencoder (VAE) to model global anatomical priors, a Generative Adversarial Network (GAN) for generating visually realistic textures, and an attention mechanism that adaptively prioritizes damaged regions during reconstruction. Trained on annotated CT and MRI datasets from public repositories such as BraTS and TCIA, the model optimizes a hybrid loss function combining pixelwise, adversarial, and perceptual components to balance accuracy and realism. Extensive quantitative evaluations demonstrate the superiority of the proposed method over traditional models. It achieves a Peak Signal-toNoise Ratio (PSNR) of 31.2 dB, Structural Similarity Index (SSIM) of 0.91, Fréchet Inception Distance (FID) of 32.6, and an average Radiologist Grading Score (RGS) of 4.6 out of 5. Furthermore, the model is successfully deployed on a Raspberry Pi 4B, achieving 2.1 frames per second (FPS) inference, validating its real-time applicability in low-power settings. This framework offers a scalable, cost-effective solution to bridge the diagnostic imaging gap in under-resourced healthcare environments.
Reference Key
chityala2025generative Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Shylaja Chityala
Journal International Journal of Health Sciences and Engineering
Year 2025
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.