Electrochemical thrombin aptasensor based on using magnetic nanoparticles and porous carbon prepared by carbonization of a zinc(II)-2-methylimidazole metal-organic framework.
Clicks: 265
ID: 29411
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
63.5
/100
265 views
215 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #50 of 75 articles by views in Mikrochimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A homogeneous electrochemical aptasensor was obtained by modifying a glassy carbon electrode (GCE) with a porous carbon nanomaterial (Z-1000, about 70 nm, deteced by transmission electron microscopic) that was obtained by carbonization of a zinc(II)-2-methylimidazole metal-organic framework. Z-1000 possesses a large specific surface and outstanding electrochemical properties. A thrombin-binding aptamer (CP) was immobilized on the magnetite nanoparticles MNPs by the condensation reaction and further combined with reporter probe (RP) that is functionalized with electroactive methylene blue (MB). In the presence of thrombin, the CP was specifically recognized with it to form the CP/MNP/Thb complex, and the RP was dissociated from MNPs. The released RP was captured by the modified GCE through π-stacking interaction between nucleobases and carbon nanostructure. The electrical signal generated by MB can be monitored by differential pulse voltammetry (DPV). Under the optimized conditions, the DPV peak current at around -0.28 V (vs. SCE) increases with thrombin concentration. The sensor has a detection limit of 0.8 fM of thrombin and a linear range that extends from 10 fM to 100 nM. It was successfully applied to the analysis of spiked serum. The recoveries are 98.1-99.4% and RSDs are 3.9%-4.0%. Conceivably, this aptasensor scheme can be easily extended to other proteins and gives inspiration to manufacture sensitive aptasensor. Graphical abstract A homogeneous electrochemical aptasensor is obtained by modifying a glassy carbon electrode with the MOF-derived porous carbon. The sensor has a detection limit of 0.8 fM and a wide linear range from 10 fM to 100 nM for thrombin detection.
| Reference Key |
ren2019electrochemicalmikrochimica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ren, Qian;Xu, Xianzhen;Cao, Guangping;Xia, Jianfei;Wang, Zonghua;Liu, Qingyun; |
| Journal | Mikrochimica acta |
| Year | 2019 |
| DOI |
10.1007/s00604-019-3781-2
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.