The influence of the chosen in vitro bone simulation model on intraosseous temperatures and drilling times.

Clicks: 160
ID: 29355
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1,395 of 1,628 articles by views in Scientific reports

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,628 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
There is no consensus about the most suitable in vitro simulating material investigating heat generation during bone preparation. The aim was to compare heat increases and drilling times of bone removals in different bone simulating materials and to compare them to fresh human cadaver bone. A cavity was drilled in the following samples: (1) bovine rib; (2) pig rib; (3) 20 PCF (lb/ft) polyurethane (PU) block with 3 mm (50 PCF) cortical layer; (4) 20PCF PU without cortical; (5) 30 PCF PU with 2 mm (40 PCF) cortical; (6) 30 PCF PU with 1 mm (40 PCF) cortical; (7) 30PCF PU without cortical; (8) poly-methyl-methacrylate (PMMA); (9) fresh human cadaver rib. Data were analyzed with ANOVA followed by Tukey's post hoc tests. P < 0.05 was considered significant. Highest heat increases and slowest drilling times were found in bovine ribs (p < 0.001). Regarding temperatures, human ribs were comparable to the pig rib and to PUs having cortical layers. Considering drilling times, the human rib was only comparable to the 20 PCF PU with 3 mm cortical and to 30 PCF PU without cortical. By the tested in vitro bone removals, only the 20 PCF PU with 3 mm cortical was able to simulate human ribs, considering both temperature increases and drilling times.
Reference Key
szalma2019thescientific Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Szalma, József;Lovász, Bálint V;Vajta, László;Soós, Balázs;Lempel, Edina;Möhlhenrich, Stephan C;
Journal Scientific reports
Year 2019
DOI
10.1038/s41598-019-48416-6
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.