Combination of Simple Diagnostic Tests to Detect Primary Angle Closure Disease in a Resource-constrained Region.

Clicks: 401
ID: 29301
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #2 of 9 articles by views in ophthalmic epidemiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
: To report on diagnostic accuracy of van Herick (vH) technique performed by a vision technician (VT) as well as on efficacy of a combination of vH technique and central anterior chamber depth (ACD) in detection of primary angle closure disease. : Data was obtained from two cohorts; rural clinic setting (n = 111), and rural population-based research setting (n = 888). Van Herick grading was performed by a VT in first cohort and a glaucoma specialist in second cohort. A reference standard four-mirror gonioscopy was performed by a glaucoma specialist in both cohorts. We did preferential sampling. Cut-off levels for vH technique and central ACD were grade 2 and 25 percentile value, respectively. Data from one eye per participant was analyzed. : Three hundred and forty (34%) eyes were gonioscopically occludable. Area under receiver operating characteristic curve (95% confidence interval) for vH test was 0.83 (0.76, 0.9) and 0.81 (0.78, 0.84) in first and second cohorts, respectively. Simultaneous testing achieved sensitivity of 87.8% while sequential testing achieved specificity of 99.3%. Negative predictive value* of simultaneous testing was 98.3% compared to 96.6% of vH technique while positive predictive value* of sequential testing was 86% compared to 49.3% of vH technique. (*at 10% prevalence of gonioscopically occludable angle) : Diagnostic accuracy of vH grading was similar when performed by a VT and a glaucoma specialist. While test combination was effective to rule in, vH technique may suffice to rule out the disease. Implications of these findings for resource-constrained regions are discussed.
Reference Key
choudhari2019combinationophthalmic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal ophthalmic epidemiology
Year 2019
DOI
10.1080/09286586.2019.1650380
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.