Accuracy of computer-assisted vertical cup-to-disk ratio grading for glaucoma screening.
Clicks: 228
ID: 29300
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
61.8
/100
228 views
186 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1,481 of 2,056 articles by views in PloS one
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 2,056 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Glaucoma screening can be performed by assessing the vertical-cup-to-disk ratio (VCDR) of the optic nerve head from fundus photography, but VCDR grading is inherently subjective. This study investigated whether computer software could improve the accuracy and repeatability of VCDR assessment.In this cross-sectional diagnostic accuracy study, 5 ophthalmologists independently assessed the VCDR from a set of 200 optic disk images, with the median grade used as the reference standard for subsequent analyses. Eight non-ophthalmologists graded each image by two different methods: by visual inspection and with assistance from a custom-made publicly available software program. Agreement with the reference standard grade was assessed for each method by calculating the intraclass correlation coefficient (ICC), and the sensitivity and specificity determined relative to a median ophthalmologist grade of ≥0.7.VCDR grades ranged from 0.1 to 0.9 for visual assessment and from 0.1 to 1.0 for software-assisted grading, with a median grade of 0.4 for each. Agreement between each of the 8 graders and the reference standard was higher for visual inspection (median ICC 0.65, interquartile range 0.57 to 0.82) than for software-assisted grading (median ICC 0.59, IQR 0.44 to 0.71); P = 0.02, Wilcoxon signed-rank test). Visual inspection and software assistance had similar sensitivity and specificity for detecting glaucomatous cupping.The computer software used in this study did not improve the reproducibility or validity of VCDR grading from fundus photographs compared with simple visual inspection. More clinical experience was correlated with higher agreement with the ophthalmologist VCDR reference standard.
| Reference Key |
snyder2019accuracyplos
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Snyder, Blake M;Nam, Sang Min;Khunsongkiet, Preeyanuch;Ausayakhun, Sakarin;Leeungurasatien, Thidarat;Leiter, Maxwell R;Sevastopolsky, Artem;Joye, Ashlin S;Berlinberg, Elyse J;Liu, Yingna;Ramirez, David A;Moe, Caitlin A;Ausayakhun, Somsanguan;Stamper, Robert L;Keenan, Jeremy D; |
| Journal | PloS one |
| Year | 2019 |
| DOI |
10.1371/journal.pone.0220362
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.