Primary orbital reconstruction with selective laser melted core patient-specific implants: overview of 100 patients.
Clicks: 301
ID: 29258
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
67.9
/100
301 views
202 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #5 of 7 articles by views in the british journal of oral & maxillofacial surgery
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Contemporary advances in technology have enabled the transfer of industrial laser melting technology to surgery, and its use can improve the accuracy of orbital restoration. The aim of this study therefore was to evaluate the accuracy of primary orbital reconstruction with the use of selective laser melted, patient-specific implants and navigation. A total of 100 patients with complex orbital fractures were included. Planned orbital volumes were compared with those achieved, and angles were compared with the unaffected side. Analysis included the overlay of postoperative on planned images (iPlan 3.0.5, Brainlab). The mean (SD) orbital volume of the unaffected side was 27.2 (2.8)ml in men and 25.0 (2.6)ml in women. Fractures that involved the posterior third of the orbital floor and comminuted fractures showed significant orbital enlargement (p=0.026). The mean (SD) reconstructed orbital volume was 26.9 (2.7)ml in men and 24.26 (2.5)ml in women. Three-dimensional analysis of the colour mapping showed minor deviations when compared with the unaffected side. The results suggest that a high degree of accuracy can be routinely achieved in these complex cases.
| Reference Key |
rana2019primarythe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Rana, M;Holtmann, H;Rana, M;Kanatas, A N;Singh, D D;Sproll, C K;Kübler, N R;Ipaktchi, R;Hufendiek, K;Gellrich, N-C; |
| Journal | the british journal of oral & maxillofacial surgery |
| Year | 2019 |
| DOI |
S0266-4356(19)30280-3
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.