Mechanical properties tailoring of topology optimized and selective laser melting fabricated Ti6Al4V lattice structure.

Clicks: 191
ID: 29249
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #34 of 41 articles by views in Journal of the mechanical behavior of biomedical materials

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This paper investigates the effect of porosity and unit cell size variation in topology optimized (TOP) and selective laser melting (SLM) fabricated Ti6Al4V lattice structure on the mechanical properties including compressive strength, failure mechanism and dynamic elastic modulus. Meanwhile, mathematical relations between mechanical properties and geometric parameters are obtained based on Gibson-Ashby model. The results show that both ultimate compressive strength (σ = 23∼498 MPa) and dynamic elastic modulus (E = 3.5∼55.47 GPa) of TOP lattice structures gradually decrease with the increase in porosity and unit cell size. The analysis combining experimental and numerical results indicates that TOP lattice structures are elastic-brittle porous material and have two failure mechanisms. The numerical predicted stress-strain curves are compared with the experimental ones. The numerical models incorporating the Johnson-Cook damage model could predict the slip direction of 45° failure band and ultimate compressive strength. Classical Gibson-Ashby model was used to predict the relation between relative density and mechanical properties of lattice structures. The exponential factors (n) of fitted models are obviously affected by unit cell size, which are determined by the number of unit cells in compressive test and SLM manufacturability in dynamic elastic modulus test. A 3D Modulus-Density-Unit Cell Size model is innovatively proposed, which can provide theoretical basis of tailoring orthopedic implant filled with functional gradient TOP lattice structures.
Reference Key
xu2019mechanicaljournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Xu, Yangli;Zhang, Dongyun;Hu, Songtao;Chen, Runping;Gu, Yilei;Kong, Xiangsen;Tao, Jiongming;Jiang, Yijian;
Journal Journal of the mechanical behavior of biomedical materials
Year 2019
DOI
S1751-6161(19)30465-5
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.