Automated anterior chamber angle pigmentation analyses using 360° gonioscopy.
Clicks: 319
ID: 29088
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
78.9
/100
319 views
214 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #10 of 14 articles by views in the british journal of ophthalmology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To assess the pigmentation distribution in the iridocorneal angle using an established algorithm with gonioscopically obtained images.Manual and automatically modified Scheie's pigmentation grading (ie, 0/I=0, II=1 and III/IV=2) of trabecular meshwork was performed using an established algorithm on the 75 open-angle eyes of 75 subjects obtained by automated gonioscopy. All images were collected at the Matsue Red Cross Hospital in 2016. The differences in the pigmentation density were compared statistically between the automated and manual techniques and among the four sectors (ie, inferior, superior, temporal and nasal) and the four quadrants.There was substantial agreement between both grading methods (kappa value=0.70). There was no significant difference between the automated and manual grading in any sectors except for the superior (p=0.0004). The automated pigmentation grade was significantly (p<0.05) higher in the inferior sector (mean grade, 1.43) than in the others (mean grade, 0.48~0.76), and it was also significantly (p<0.05) higher in the inferior quadrant (mean grade, 3.56) than in the others (mean grade, 1.64~2.24). The findings were similar for manual grading.The entire distribution of the pigmentation in the anterior chamber angle was classified successfully using the algorithm, and the automated versus manual grading comparison showed good agreement. The automated pigmentation grading scores in the inferior sector and inferior quadrant were significantly higher than in the others as previously reported. Similar findings also were seen for manual grading.
| Reference Key |
matsuo2019automatedthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Matsuo, Masato;Pajaro, Simone;De Giusti, Andrea;Tanito, Masaki; |
| Journal | the british journal of ophthalmology |
| Year | 2019 |
| DOI |
bjophthalmol-2019-314320
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.