New photothermal immunoassay of human chorionic gonadotropin using Prussian blue nanoparticle-based photothermal conversion.
Clicks: 251
ID: 29054
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
68.1
/100
251 views
208 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #42 of 90 articles by views in Analytical and bioanalytical chemistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A new near-infrared-based photothermal immunosensing strategy was developed for the sensitive and feasible detection of human chorionic gonadotropin (HCG) by use of a Prussian blue nanoparticle-based photothermal conversion system. Prussian blue nanospheres synthesized by the one-pot method were used for the labeling of anti-HCG detection antibody. A sandwich-type immunoreaction was initially conducted on a monoclonal anti-HCG antibody-coated microplate with a nanoparticle-labeled signal antibody. Accompanying formation of the sandwiched immunocomplex, Prussian blue nanospheres caused photothermal conversion under 980-nm laser irradiation, thereby resulting in an increase of the temperature of the detection system measured by a portable digital thermometer. The properties and factors influencing the analytical performance of the photothermal immunoassay were studied in detail. Under the optimal conditions, the Prussian blue nanoparticle-based photothermal immunoassay exhibited good temperature responses relative to target HCG concentrations within the dynamic range of 0.01-100 ng mL at a low detection limit of 5.8 pg mL. This system also displayed good anti-interference behavior with regard to other cancer biomarkers, good reproducibility, and relatively long storage stability. The method accuracy was evaluated for analysis of human serum specimens, giving results that matched well with those obtained with a commercial HCG enzyme-linked immunosorbent assay kit. Importantly, this protocol is promising for advanced development of photothermal immunoassays. Graphical abstract.
| Reference Key |
hong2019newanalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Hong, Guolin;Zhang, Dongdong;He, Yinghao;Yang, Yuanyuan;Chen, Ping;Yang, Huijing;Zhou, Zhiyang;Liu, Yinhuan;Wang, Yan; |
| Journal | Analytical and bioanalytical chemistry |
| Year | 2019 |
| DOI |
10.1007/s00216-019-02049-w
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.