Structural and mechanical characterization of custom design cranial implant created using additive manufacturing

Clicks: 356
ID: 28815
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #7 of 33 articles by views in electronic journal of biotechnology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: Reconstruction of customized cranial implants with a mesh structure using computer-assisted design and additive manufacturing improves the implant design, surgical planning, defect evaluation, implant-tissue interaction and surgeon's accuracy. The objective of this study is to design, develop and fabricate cranial implant with mechanical properties closer to that of bone and drastically decreases the implant failure and to improve the esthetic outcome in cranial surgery with precision fitting for a better quality of life. A customized cranial mesh implant is designed digitally, based on the Digital Imaging and Communication in Medicine files and fabricated using state of the Art-Electron Beam Melting an Additive Manufacturing technology. The EBM produced titanium implant was evaluated based on their mechanical strength and structural characterization. Results: The result shows, the produced mesh implants have a high permeability of bone ingrowth with its reduced weight and modulus of elasticity closer to that the natural bone thus reducing the stress shielding effect. Scanning electron microscope and micro-computed tomography (CT) scanning confirms, that the produced cranial implant has a highly regular pattern of the porous structure with interconnected channels without any internal defect and voids. Conclusions: The study reveals that the use of mesh implants in cranial reconstruction satisfies the need of lighter implants with an adequate mechanical strength, thus restoring better functionality and esthetic outcomes for the patients.
Reference Key
moiduddin2017structuralelectronic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Moiduddin, Khaja;Darwish, Saied;Al-Ahmari, Abdulrahman;ElWatidy, Sherif;Mohammad, Ashfaq;Ameen, Wadea;
Journal electronic journal of biotechnology
Year 2017
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.