Towards ultra-high peak capacities and peak-production rates using spatial three-dimensional liquid chromatography.

Clicks: 220
ID: 28790
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #14 of 18 articles by views in lab on a chip

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In order to successfully tackle the truly complex separation problems arising from areas such as proteomics research, the development of ultra-efficient and fast separation technology is required. In spatial three-dimensional chromatography, components are separated in the space domain with each peak being characterized by its coordinates in a three-dimensional separation body. Spatial three-dimensional (3D-)LC has the potential to offer unprecedented resolving power when orthogonal retention mechanisms are applied, since the total peak capacity is the product of the three individual peak capacities. Due to parallel developments during the second- and third-dimension separations, the analysis time is greatly reduced compared to a coupled-column multi-dimensional LC approach. This communication discusses the different design aspects to create a microfluidic chip for spatial 3D-LC. The use of physical barriers to confine the flow between the individual developments, and flow control by the use of (2)D and (3)D flow distributors is discussed. Furthermore, the in situ synthesis of monolithic stationary phases is demonstrated. Finally, the potential performance of a spatial 3D-LC systems is compared with the performance obtained with state-of-the-art 1D-LC and (coupled-column) 2D-LC approaches via a Pareto-optimization approach. The proposed microfluidic device for 3D-LC featuring 16 (2)D channels and 256 (3)D channels can potentially yield a peak capacity of 8000 in a total analysis time of 10 minutes.
Reference Key
wouters2015towardslab Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Wouters, Bert;Davydova, Ekaterina;Wouters, Sam;Vivo-Truyols, Gabriel;Schoenmakers, Peter J;Eeltink, Sebastiaan;
Journal lab on a chip
Year 2015
DOI
10.1039/c5lc01169h
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org