Characterization and cost-benefit analysis of 3D-printed acrylonitrile butadiene styrene (ABS) dry conductive electrodes as reusable electrodes for surface electromyography (EMG) applications
Clicks: 5
ID: 287217
2022
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
1.2
/100
5 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #221 of 3,757 articles by views in Malay Journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study investigated the use of 3D-printed dry electrodes for surface electromyography (sEMG). Solid freeform fabrication (SFF) and fused deposition modeling (FDM) is a promising fabrication method that has potential applications in EMG, especially in developing wearable EMG. A 3D printer was used to fabricate conductive acrylonitrile butadiene styrene (ABS) electrodes in different layer heights. The 3D printed electrodes’ Young’s and Shear Moduli and tensile and shear yield, ultimate, and fracture points were determined using a Materials Testing System. The arithmetic average roughness height, Ra, and the root mean square roughness, Rq, of the printed electrodes’ surfaces were quantified through macro imaging and image processing and analysis software. The resistances of the electrodes were also measured using a digital multimeter. A comparative analysis between the signal-to-noise ratio (SNR) of the printed conductive ABS electrodes and the commercial standard Ag/AgCl electrodes. A cost-benefit analysis was also undertaken to determine the cost-effectiveness of the 3D-printed conductive ABS electrodes compared to the commercial standard Ag/AgCl electrodes. The 3D-printed conductive ABS electrodes were then attached to the volunteer’s biceps brachii muscle and corresponding EMG data was eventually fetched using the MyoWare muscle sensor module. Statistical analysis has shown that there was no significant differences between the SNRs of the 3D-printed conductive ABS electrodes and the commercial standard Ag/AgCl electrodes when used for EMG on biceps as Myoware Muscle sensors. Although 3D-printed conductive ABS electrodes has shown the highest SNR with layer height of 0.20 mm. With tensile strength of 1.53 ± 0.01 Gpa and shear stress of 0.15 ± 0.01 Gpa empirically derived for ABS filament material using PASCO ME-8244 Tensile-Sress Test, optimal SNR performance was observed for 3d-printed conductive ABS electrodes with a layer height of 0.20 mm and surface roughness of 26.01 nm. Furthermore, the cost-benefit analysis has shown that the cost-effectiveness of the printed electrodes, specifically with layer heights of 0.16mm and 0.20mm, was comparable to that of the Ag/AgCl electrode with Php 0.02/use difference. Thus, 3D-printed ABS dry conductive electrodes can be an alternative electrode besides commercial standard Ag/AgCl electrodes with no significant technical difference in terms of its SNR values and with comparable cost-effectiveness in terms of price per use value.
| Reference Key |
persistent_1760660931_68f18dc348cd8
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Dulay, Alex Philippe V. |
| Journal | Malay Journal |
| Year | 2022 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.