In silico analysis of aptamer for cortisol detection on biosensing applications

Clicks: 1
ID: 287216
2022
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #3,629 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We performed an in-silico approach in determining which aptamers would exhibit the strongest binding affinity to cortisol and compared it to the reference receptor Glucocorticoid receptor by analyzing the intermolecular forces (e.g. electrostatic forces and Van der Waals forces) of both enthalpic and entropic hydrophilicity using mFold, RNAComposer, Autodock Tools, Autodock Vina, PyMOL and Discovery Studio Visualizer application software programs. Since the molecules (i.e. ligand and receptor molecule) are nucleic acids and steroid hormone, respectively, molecular dynamics simulation for these types of molecules were prohibitive in terms of computer resources (e.g. memory size and processor speed) and computer access that requires a high performance computer grade facility. The aptamers were observed to fold into stacked pairs, interior loops, and external loops, among other structural components. Molecular docking analysis revealed that the Glucocorticoid Receptor (PDBID 6NWK) has a binding energy of -11.3 kcal/mol and Aptamer 8 had the strongest binding affinity to cortisol (-9.3 kcal/mol). Discovery Studio Visualizer identified that the hydrogen bonding interaction dominated among other interactions between Aptamer 8 and Cortisol, which is an important factor in establishing stability in the complex structure of both molecules. As Aptamer 8 exhibited the strongest binding affinity, it may be considered an alternative receptor for a Glucocorticoid receptor for cortisol detection in designing new sensors for medical instrumentation applications. Keywords: In-silico, Analysis, Aptamers, Cortisol, Glucocorticoid, Receptor, Nucleic Acids, Hormone, Intermolecular Forces, Molecular Docking
Reference Key
persistent_1760660928_68f18dc064a2c Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Redoble, Bea Eillen Joy S.
Journal Malay Journal
Year 2022
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.