Non-invasive blood glucose monitoring using acetone sensor
Clicks: 1
ID: 287211
2022
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #3,614 of 3,757 articles by views in Malay Journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Diabetes is currently the leading cause of death in the world, and is caused by a disordered metabolism that raises blood glucose levels. This cause makes it imperative that researchers in the field of medicine find ways to monitor, prevent, and diagnose people without the need for intrusive, and painful procedures. Volatile organic compounds or VOCs have been studied to be great indicators of metabolic diseases thus allowing a better alternative to the traditional finger pricking method. Acetone, usually found in the blood and breath, has been investigated to be a significant ketone biomarker, which has been found to be an excellent indicator of diabetes mellitus. This study aims to create an Arduino-based biosensor using a TGS822 sensor that would allow the measurement of acetone concentrations in the breath of diabetic and non-diabetic participants and to correlate these findings with their blood glucose levels taken before and after meals. In addition, to validate the correlation, a calibration curve must be created. The study made use of experimental methods, which included six participants, excluding the researchers, who were evenly divided into diabetic and non-diabetic individuals. The researchers also managed to test themselves to generate data to be compared against data taken from the calibration curve. Results show a strong positive correlation between the variables, with an r value of 0.802 and an r squared value of 0.643 for both diabetics and non-diabetics. Additionally, a low error margin was found taken from the calibration curve, thus indicating that acetone could be used to monitor glucose levels in the body, thus leading to the conclusion that breath acetone may be a promising biomarker for diabetes detection.
| Reference Key |
persistent_1760660914_68f18db27270c
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Huang, Julianna Yzabel L. |
| Journal | Malay Journal |
| Year | 2022 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.