Noninvasive monitoring of blood glucose and skin hydration level using paired photo-emitter and detector infrared LED

Clicks: 1
ID: 287209
2022
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #3,698 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
At present, diabetes remains to be a prevalent disease as cases are still on the rise with no signs of decline. Studies have shown that the global prevalence of diabetes is projected to increase from 463 million (9.3%) in 2019 to 578 million (10.4%) in 2030 and will eventually climb to 700 million (10.9%) [1]. As of the moment, there has been no developed cure for the said disease. Instead, proper monitoring is needed in order to regulate and treat one’s unstable blood glucose level. Another factor to be considered in diabetes is dehydration since this could also lead to a series of complications. The most common way to monitor one’s blood is by pricking the finger and inputting drops of blood into a glucometer. Thus, in this study, an alternative option was explored which was the use of a noninvasive glucose monitoring device. The study made use of two infrared LEDs bought from a local electronics store which served as both the transmitter and receiver for the setup. The research was able to produce a consistent voltage reading for the monitoring of both blood glucose concentration and skin hydration level. The average percent difference between the invasive and noninvasive methods was calculated to be 3.39%. It was also concluded that the noninvasive device created is within the ISO 15197:2013 standard. Furthermore, 90% of the data gathered from the noninvasive method was classified as a “none” risk level and the remaining 10% as a “slightly lower” risk level for the surveillance grid analysis. The average percent difference between the commercial skin moisture detector and the noninvasive device was determined to be 5.33%. Lastly, the study was able to conclude that there is a very strong negative relationship between blood glucose concentration and skin moisture level.
Reference Key
persistent_1760660908_68f18dacb07b9 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Irie, Myka Andrea C.
Journal Malay Journal
Year 2022
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.