Design, fabrication and performance testing of stationary freezer of Jollibee Food Corporation using non-CFC refrigerator (R-404A)

Clicks: 1
ID: 287008
2003
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #3,408 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
In general, the project study has provided the author a vast experience especially during the brainstorming stage where different problems occurred during the performance testing. The author was very glad to the previous theoretical lectures of Dr, Maglaya who was also my former professor in the subjects Advance Refrigeration and Air-conditioning during my undergraduate and graduate class in the De La Salle University. Thru his teachings and guidance, The author was able to apply the theoretical knowledge the author has learned in combating actual job problems experienced in the company. The project was very challenging because of the swift output during the testing and then making the necessary adjustments in order to attain the desired results. In addition, this project is a pioneer project of Chee Puck Refrigeration Inc that gave me a lot of pressure but the author is honored to have the privilege in embarking this task. The major concentration of the project study was to design, fabricate, and conduct a performance testing of stationary freezer using R-404A, a non-CFC refrigerant. The results of the performance testing shows that the evaporating temperature of negative twenty degree Celsius (–20C) within 25 minutes were reach, which is the main requirements set by Jollibee Foods Corporation to Chee Puck Refrigeration Inc. In addition, the unit case was also subjected to severe physical testing by opening and closing the door with significant pressure on the boundaries of normal usage in order to test the physical toughness of the unit. Results show that the design and fabrication was very tough and formidable because it withstood significant pressures applied to unit case.
Reference Key
persistent_1760660316_68f18b5c46460 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Chee, Kenways S.
Journal Malay Journal
Year 2003
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.