Design and experimental analysis of a combined target fluidic and centrifungal pump system as a tachometer transducer
Clicks: 1
ID: 287007
2004
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #3,378 of 3,757 articles by views in Malay Journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
This study aims to design an alternative tachometer transducer using a combined target fluidic and centrifugal pump system. The design was based on the previous study done by Lua A., Zheng Z., 2003. Fluidics (2Fluid3 + 2Logic3) devices use fluids to perform functions of electrical or electronic systems. A target fluidic is a kind of fluidic device that produces jet or stream oscillation. It was first patented by Huang B.T. (1995), Flowmeter Having a Fluidic Oscillator, United States Patent No. 5,396,809. An apparatus comprising of a target fluidic and centrifugal pump system was constructed based on dimensions from Lua A. and Zheng Z. (2003) with input signal from the centrifugal pump whose speed is varied using a frequency inverter. The experimental setup involves different position of the target fluidics nozzle and target wall. The oscillating jet stream (output signal) produced by the target fluidic was recorded using a video camera and using a video analyzing and editing software the frequency of the jet oscillation was computed. The pump rotating frequency, as the input signal, was measured using a hand tachometer. Results show that the relationship between the input signal (pump speed) and output signal (jet oscillation frequency) is linear irregardless of the position of the nozzle and the target wall. And since the values measured are stable and unique at each point, the combined target fluidic and centrifugal pump system will indicate a measured value of the input speed based on the frequency of the oscillation of the jet stream.
| Reference Key |
persistent_1760660313_68f18b59b3407
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Uy, Lawrence K. |
| Journal | Malay Journal |
| Year | 2004 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.