An energy audit study of Cavite State University Indang, Cavite
Clicks: 1
ID: 287006
2005
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #3,598 of 3,757 articles by views in Malay Journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The Energy Audit Study of Cavite State University was conducted at Don Severino Delas Alas campus, barangay Bancod Indang Cavite.The audit process is an organized approach to identify how well energy resources are used and wasted in the university, and to determine how this waste can be eliminated at a reasonable cost.During the process, data were gathered through visual walkthrough inspection, surveys, interviews to personnel-in- charge, and gathering data/documents pertaining to energy cost consumption.The major energy source used in the university was electricity for power, lighting, and water generation and distribution. Minor energy sources are petroleum products, diesel and gasoline used for transportation, hauling and other auxiliary services.The detailed energy audit study focuses on the 11 out of 50 existing functional facilities and buildings and was identified as cost centers. Instruments were installed for one-month period to determine the specific electrical energy used per cost center.Based on the study a considerable amount of electrical energy is wasted during noon breaks or lunch break (12:00 – 1:00 p.m.) wherein most facilities such as lighting and air-conditioning systems are left open at offices and classrooms even though there are no occupants.Energy savings concepts were identified to reduce electric bill such as demand limiting, proper maintenance and best operating practices.
| Reference Key |
persistent_1760660310_68f18b56e87fb
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Peña, Ronald P. |
| Journal | Malay Journal |
| Year | 2005 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |