Design of a hand wearable device for grasping with kinematic simulation

Clicks: 1
ID: 286673
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #3,746 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The purpose of this study is to design a hand wearable device for grasping in order to provide assistance during rehabilitation. Indeed, human hands are crucial in activities of daily living. However, disability from stroke or injury remains to be the leading cause of impairment worldwide. Thus, repetitive exercises and strengthening activities are important to regain motor function and improve quality of life of patients affected by hand impairments. Currently, robotic exoskeletons have been developed to assist in the rehabilitation process but because of the complexity of the human hand, there pose a challenge to deliver meaningful manipulation capabilities in a small and lightweight package. In the design of the hand exoskeleton, the anatomy of the hand is reviewed and considered to ensure biocompatibility between the actual user and the device. A prototype of the device is fabricated to provide complete flexion and extension motion of individual fingers of the right hand. This robotic system uses a cable-driven mechanism consists of cables attached to the fingertips through cable guides. The design of the glove can be secured and aligned to individual wearers to ensure adaptability. To test the device, a mechanical hand was 3D printed and was used to verify the compatibility of the glove. As a result, the device was able to provide the grasping motion. Finally, the design was evaluated and validated by the medical doctors of the Department of Rehabilitation Medicine at Philippine General Hospital. Overall, the design and development of a hand robotic exoskeleton prototype for upper limb therapy was successful. This rehabilitation device through its design and features aims to improve the accessibility and reliability of stroke and injury therapy not only in the Philippines but in the developing regions as well.
Reference Key
persistent_1760659302_68f187660aa54 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ong, Aira Patrice R.
Journal Malay Journal
Year 2016
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.