EMG-based hand gesture recognition for active-assistive rehabilitation
Clicks: 2
ID: 286657
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
2 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #3,443 of 3,757 articles by views in Malay Journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Physical disabilities affect many people worldwide, but therapies and rehabilitation can help one’s recovery. Rehabilitation can be done manually. However, modern developments in technology enabled the use of robotics in rehabilitation, and has proved to be with comparable effectivity with manual rehabilitation. In line with this, a locally developed rehabilitation for upper limb extremities was developed. Regarding features, it can be at par with commercially available rehabilitation devices. To further improve the developed device, an algorithm to assist the user while rehabilitation is studied. Electromyography (EMG) based signals were used for input. Multiple models were compared, namely artificial neural networks (ANN), support vector machines (SVM), and recurrent neural networks (RNN). Six feature extraction techniques were used for training. These are integrated EMG (IEMG), root-mean-square (RMS), discrete wavelet transform (DWT), fast Fourier transform (FFT), waveform length (WL), and zero crossing (ZC). The best performing algorithm based on processing speed and training time was with IEMG as feature extraction technique, and ANN as training algorithm. Recorded training time was at 21 seconds, with the model’s accuracy averaging at 96.3% and its processing time logged at 203 milliseconds. It was also interfaced with the existing rehabilitation device via simulation. Future directives include baseline compensation, correction techniques for muscle fatigue, and gathering data from healthy subjects and actual stroke patients.
| Reference Key |
persistent_1760659247_68f1872f9fd9f
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Cases, Carlos Matthew P. |
| Journal | Malay Journal |
| Year | 2020 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.