Offline machine learning-based concurrent and rapid determination of acetaminophen, dextromethorphan, guaifenesin, and phenylephrine using UV-vis spectroscopy

Clicks: 5
ID: 286654
2021
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #309 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Currently, wet chemistry techniques such as HPLC dominate the pharmaceutical industry when complying with API content testing. UV-Vis spectroscopy proved to be an efficient and nondestructive method that could potentially obtain API assays simultaneously. However, its performance becomes limited due to severely overlapped spectra, such as the case of Acetaminophen (APAP), Dextromethorphan HBr (DEX), Guaifenesin (GUA), and Phenylephrine HCl (PHE) combination drug. Therefore, four machine learning models, namely, Partial Least Squares Regression (PLSR), Support Vector Regression (SVR), Random Forest Regression (RFR), and Artificial Neural Network (ANN), were developed, optimized, and tested that would breach this limitation. Subsequently, the four developed models were compared to each other, with ANN having R2 correlations of 99.96% for APAP, 95.65% for DEX, 99.51% for GUA, and 90.08% for PHE, which outperforms the three models. Finally, the optimum ANN model was validated, resulting in correlations of 99.25% for APAP, 95.61% for DEX, 99.34% for GUA, and 89.38% for PHE, proving its capability to generalize its prediction of API concentrations.
Reference Key
persistent_1760659215_68f1870fc7622 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Felipe, Mikhael Anthony A.
Journal Malay Journal
Year 2021
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.