Design of a mini-braille cell using SMA-based actuators

Clicks: 1
ID: 286646
2023
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #3,178 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Over 39 million people are afflicted with blindness in the world today. The Braille code is the alphabet used for the education and activities of daily life (ADL) of the blind and visually impaired (BVI). Refreshable braille displays (RBD) are electronic devices capable of outputting braille characters. However, these displays are still much larger compared to typical electronic displays. While voice inputs and outputs can be used by the BVI, a codified language still has its own advantages for specific ADL. With the advent of wearable devices in the past years, RBDs that can be integrated into such can open the technology to BVIs and present new market opportunities. This study presents a novel design for a mini-braille cell using actuators made from shape memory alloys (SMA). The housing is designed using CAD software and printed in a DLP 3D printer. The SMA-actuators were created from SMA wires that were programmed using a bending method that was developed and honed for this study. An Arduino microcontroller was used to operate the prototype. A PWM control scheme was implemented to regulate the heat required by the SMA-actuator. The resulting mini-braille cell was tested and compared with a commercially available RBD, the Metec P20 braille cell. The final prototype, though built at 150% scale of the original design, is still smaller by 59.5% in volume and lighter by 25% with the final dimensions of 25.5mm by 9.2mm by 8.1mm and a weight of 3g. The output force of the raised braille dots was greater by 300%, lifting at least 75g of load. However, while the actuation force was improved, the refresh rate is slower. The prototype was demonstrated to be capable of displaying different braille characters. However, heat bleeds from activated braille dots to inactivated ones, resulting in errors in the character display. These issues may be addressed in the future by improving the design and precision of the manufacturing of its components, particularly the SMA-actuators. Fine-tuning the values used for the control scheme could also improve the functionality of the mini-braille cell.
Reference Key
persistent_1760659190_68f186f62599b Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Cortez, John Vincent P.
Journal Malay Journal
Year 2023
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.