A semi-autonomous robotic system with alignment control for the occluded object using visual servoing and computational intelligence

Clicks: 2
ID: 285998
2024
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #3,451 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Aligning a mobile X-ray system in challenging environments, such as bomb-surrounded areas, poses difficulties due to safety concerns and occlusion. This study introduces a novel approach employing 6D object pose estimation and pose correction by integrating DeepLabV3 and iterative dense fusion into the visual servoing mechanism. The robotic system exhibits enhanced accuracy in detecting and aligning the occluded known 3D object model x-ray source to film. Evaluation metrics, including intersection-over-union and mean average, demonstrate high accuracy percentages for detecting the body (98.91%), handle (96.57%), and aperture (89.54%). The mean IoU for each part of the 3D model portable X-ray source ranges from 65.69% to 76.42%. Pose estimation accuracy, assessed through the ADD metric, indicates superior performance for static pose estimation closer to the camera. Dynamic pose estimation exhibits higher average ADD metrics in scenes with total occlusion. The robustness metric reveals lower lost tracking counts in scenes without occlusion, emphasizing the algorithm's challenges in fully occluded scenarios. The film handler alignment system, characterized by kinematic formulation and actuator calibration data, shows minimal errors in X and Y actuation (
Reference Key
persistent_1760657273_68f17f798f973 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Rogelio, Jayson P.
Journal Malay Journal
Year 2024
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.