Estimation of stiffness modulus and settlement of stone column improved composite sandy soil based on in-situ tests

Clicks: 1
ID: 285148
2021
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #2,807 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Considering foundations that are to be built on areas with weak soil and high seismic activities, primary and post liquefaction settlements become a major problem that engineers must resolve. Out of several techniques available for improving the weak subsurface, stone columns technique is one of the ideal option. Stone columns increase the strength of weak soil and at the same time eliminates the occurrence of soil liquefaction during seismic activities. But a relatively bigger foundation settlement is expected with the use of stone columns as compared to other deep soil improvement methods. While there are already a lot of studies on the estimation of settlement of stone columns-improved foundations, there are only few available data gathered and analyzed based on the actual in-situ foundation settlement. This paper presented and analyzed the calculated expected settlement versus the actual settlement of five 14m diameter tank foundations with stone columns. Quality of stone columns was maintained by ensuring that the crowd pressure on the vibratory hammer reaches 100 bars before pulling it up for the next lift. The expected settlement was calculated using PLAXIS 3D Finite Element Method (FEM) of design, utilizing the stiffness modulus of stone column-improved composite soil which was derived from the result of Standard Penetration Test (SPT) between the stone columns and Static Modulus Test (SMT) done on stone column. The actual settlement of foundations was taken during the hydrotest of the five tanks. It was observed that on the average, the calculated expected settlement is 50% bigger than the actual settlement during hydrotest. It was concluded that that the bigger values of calculated expected settlement or lower value of calculated stiffness modulus of stone column improved composite soil was due to: (1)design assumption of constant minimum cross-sectional diameter of stone columns along its whole length; and (2)the under-estimation of N-SPT values of soil between the stone columns where SPT was carried out midway between the installed stone columns. A numerical factor of 1.2 can be multiplied to the calculated composite elastic modulus to balance the conservativity of the design and economic implication.
Reference Key
persistent_1760654769_68f175b107405 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Boneo, Ulysis B.
Journal Malay Journal
Year 2021
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.