Pull-out strength of an expansion stud anchor in carbon fiber reinforced concrete
Clicks: 2
ID: 285110
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
0.3
/100
2 views
1 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #3,396 of 3,757 articles by views in Malay Journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Carbon fiber reinforced concrete (CFRC) is considered as an innovative structural material because of its better performance characteristics when compared to conventional concrete. Its common applications where expansion stud anchor connection is possible are in slabs on grade, wall panel, curtain walls, and pre-cast elements. The design of this stud anchor in CFRC is of great interest to many structural engineers, however, no model is available as basis for its design. To develop such model, the pull-out strength of an expansion stud anchor embedded in CFRC as influenced by fiber volume content (Vf), fiber length (Lf), compressive strength and tensile strength were studied. Three compression, three tension, and five pull-out CFRC specimens each of different Vf (0.10%, 0.15%, 0.20%, 0.25%, 0.30%) and different Lf (19 mm, 30 mm, 38 mm) were prepared, tested, analyzed, and compared to control concrete specimens at design compressive strengths of 21 MPa, 28 MPa, and 35 MPa. Tests results show that pull-out strength of an expansion stud anchor in CFRC is maximum at Vf = 0.10% and Lf = 38 mm. Among the parameters considered, tensile strength is the most significant contributing factor that could influence the pull-out strength of stud anchor in CFRC. This is further verified numerically by a micromechanics analysis and by a FEM model with good agreement to the observed tensile strength. A response surface methodology (RSM) model was developed to predict the pull-out strength of an expansion stud anchor embedded in CFRC as influenced by the fiber volume content, compressive strength, and tensile strength. Finally, a Modified CCD model which was partly modeled by micromechanics analysis was also developed to predict the pull-out strength of an expansion stud anchor in CFRC.
| Reference Key |
persistent_1760654652_68f1753c3ce91
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Estores, Gilford B. |
| Journal | Malay Journal |
| Year | 2017 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |