Effect of different metal concentrations on ammonia detection by the salicylate method

Clicks: 1
ID: 285011
2023
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal

Ranked #2,651 of 3,757 articles by views in Malay Journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The salicylate method is an established method used to quantify ammonia in a sample. The method involves the addition of a salicylate catalyst solution, an alkaline citrate solution, and an alkaline hypochlorite solution. All of which are involved in the Berthelot reaction that produces an indophenol-like dye, which can be quantitatively measured using a spectrophotometer. Giner-Sanz et al. (2020) has determined that iron interferes with the salicylate method, inhibiting the accurate measurement of ammonia. Thus, this study determined the effect of other transition metals to the salicylate method employed. Through a series of experiments, the study was able to determine that manganese, in the form of Mn2+, dramatically decreased the visible peak at 650 nm. With an R2 = 0.989, the TAN with Mn2+ standard is a good representation of the effect of Mn2+ to the indophenol reaction in the salicylate method. In addition, calculating for the equation at which the changes in absorbance is determined by the concentration of Mn2+ the Beer law has been used and the molar absorptivity was calculated at 27.7 mM-1 cm-1. In conclusion, the effect of Mn2+ can be quantified using the Beer’s law equation, and as such could be employed to determine the specific absorbance of TAN, in the presence of Mn2+ at predetermined concentration. While the salicylate method is used to determine the concentration of ammonia, the effect of Mn2+ was found to decrease the indophenol as the concentration of the metal increased, just like the known effect of Fe3+.
Reference Key
persistent_1760654354_68f1741294fd6 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Arquelada, Joaquim Antonio V.
Journal Malay Journal
Year 2023
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.