The effects of operational parameters on the removal of pollutants from simulated tannery wastewater by electrocoagulation process
Clicks: 1
ID: 284962
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #3,311 of 3,757 articles by views in Malay Journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 3,757 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The applicability of Electrocoagulation (EC) process in the treatment of simulated tannery wastewater was studied. Wastewater had an initial sulfide S2-, COD, total chromium content of 76.277.16 mg/L, 1145.651.2 mgO2/L, and 18.20.3 mg/L, respectively. The electrode material Fe/Al as anode/cathode gave the most effective treatment as compared to Fe/Fe and Al/Al in the 1-L beaker tests. In the 18-L reactor employing Fe/Al electrodes, the effects of operational parameters, such as current density (9.6 - 48 A/m2), inner-electrode distance (10 43 mm) and recirculation flow rate (0.4 4 L/min) on the removal of sulfide, COD, total chromium, and other characteristics including pH, temperature, conductivity, dissolved oxygen, applied voltage, electrode dissolution and energy consumption was investigated. When current was applied, there was a quick change in the color of wastewater from turbid greenish blue to totally black and finally to colorless solution the pollutant abatement was obtained at 95 % of S2-, 83 90 % of COD, and 99 % of total Cr. The experiments showed that very high current density led to passivation of electrodes and ineffective treatment of wastewater. EC was suitable to work in a low mixing regime. The relationships of operational parameters and the responses, namely the removal of S2-, COD, Cr and the energy consumption, were achieved via Response Surface Methodology (RSM) employing a central composite design. The effective EC run with the minimum energy consumption was 1.052 kWh/m3 when the process was performed at 19.2 A/m2 of current density, 16 mm of inner-electrode distance, 1L/min of recirculation flow rate and 90 minutes of electrolysis time. Overall, the EC process was effective in the treatment of tannery wastewater.
| Reference Key |
persistent_1760654214_68f173868ca36
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Lieu, Uyen Tu |
| Journal | Malay Journal |
| Year | 2012 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.