4D Monte Carlo dose calculations for pre-treatment quality assurance of VMAT SBRT: a phantom-based feasibility study.
Clicks: 378
ID: 28357
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
76.3
/100
378 views
276 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #10 of 37 articles by views in Physics in medicine and biology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Volumetric arc therapy (VMAT) for lung stereotactic body radiotherapy (SBRT) is challenging due to both breathing-induced motion and the dynamic components of the linear accelerator. In this study, a 4D Monte Carlo (4DMC) dose calculation method for VMAT SBRT is proposed and the feasibility of the method is evaluated. A rigidly-moving lung phantom was imaged using four dimensional computed tomography (4DCT). VMAT SBRT plans were generated on the average intensity projection dataset using the internal target volume (ITV) strategy (ITV-plan) and a single phase to simulate a dynamic treatment-couch tracking technique (TRACKING-plan). 4DMC simulations were performed and compared to 3D Monte Carlo (3DMC) and 3D- and 4D-calculations in the treatment planning system using the adaptive convolution (AC) algorithm. Dose metrics calculated for the ITV-plan showed an overestimation with 3D adaptive convolution (3DAC) for D98%(GTV) by 3.5% and by 2.0% for 3DMC, both compared to 4DMC. The TRACKING-plan D98%(GTV) calculated with the 3DAC method overestimated by 2.0% compared with 4DMC. Deviations between the calculation methods for Dmean(Lung) and D95%(PTV) were minimal. For both plans, measurements were taken with EBT3 film inside the phantom tumor. EBT3 film profiles showed good agreement with 4DMC for the TRACKING-plan giving a gamma pass rate of 97.2% for 3%/3mm global and for 3DAC compared with measured, 95.8%. Whereas for the ITV-plan, the 3D profiles varied from film in the ITV periphery region with a pass rates of 50% and 48.6% for 3DAC and 3DMC respectively. 4DMC agreed more closely to measurements for this plan with a pass rate of 95.8%. We have proposed an accurate method to perform 4D dose calculations for pre-treatment quality assurance of VMAT SBRT. The method was compared to experimental measurements and for both plans, 4DMC dose agreed with measurements more closely than other evaluated dose calculation methods. This study has demonstrated the feasibility of this 4DMC method.
| Reference Key |
roberts20194dphysics
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Roberts, Natalia Frances;Williams, Matthew;Holloway, Lois;Metcalfe, Peter;Oborn, Brad M; |
| Journal | Physics in medicine and biology |
| Year | 2019 |
| DOI |
10.1088/1361-6560/ab3fd0
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.