An Integrated Data Acquisition Approach for the Structural Health Monitoring and Real-Time Earthquake Response Assessment of a Retrofitted Adobe Church in Peru.
Clicks: 81
ID: 282755
2024
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
24.0
/100
81 views
19 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #1,669 of 1,694 articles by views in sensors
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The structural health monitoring (SHM) of buildings provides relevant data for the evaluation of the structural behavior over time, the efficiency of maintenance, strengthening, and post-earthquake conditions. This paper presents the design and implementation of a continuous SHM system based on dynamic properties, base accelerations, crack widths, out-of-plane rotations, and environmental data for the retrofitted church of Kuñotambo, a 17th century adobe structure, located in the Peruvian Andes. The system produces continuous hourly records. The organization, data collection, and processing of the SHM system follows different approaches and stages, concluding with the assessment of the structural and environmental conditions over time compared to predefined thresholds. The SHM system was implemented in May 2022 and is part of the Seismic Retrofitting Project of the Getty Conservation Institute. The initial results from the first twelve months of monitoring revealed seasonal fluctuations in crack widths, out-of-plane rotations, and natural frequencies, influenced by hygrothermal cycles, and an apparent positive trend, but more data are needed to justify the nature of these actions. This study emphasizes the necessity for extended data collection to establish robust correlations and refine monitoring strategies, aiming to enhance the longevity and safety of historic adobe structures under seismic risk.
| Reference Key |
karanikoloudis2024an
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Karanikoloudis, Georgios; Barontini, Alberto; Mendes, Nuno; Lourenço, Paulo B |
| Journal | sensors |
| Year | 2024 |
| DOI |
10.3390/s24165327
|