Complete intra-laboratory validation of a LAL assay for bacterial endotoxin determination in EBV-specific cytotoxic T lymphocytes

Clicks: 88
ID: 281390
2021
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #3 of 3 articles by views in molecular therapy: methods & clinical development

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Endotoxin content is a critical factor that affects the safety of biological pharmaceutical products. International pharmacopoeias describe several reference methods to determine endotoxin levels in advanced therapy medicinal product (ATMP) preparations. Administration of ATMPs must be done as rapidly as possible to ensure complete viability and potency of the cellular product. To evaluate the endotoxin content in the shortest time possible, we chose to validate an alternative method based on the use of the Charles River Portable Testing System (PTS) and FDA-approved cartridges, compliant with the requirements of the European Pharmacopoeia and providing results in <20 min. Here, we describe a unique and complete validation approach for instrument, personnel, and analytical method for assessment of endotoxins in ATMP matrices. The PTS system provides high sensitivity and fast quantitative results and uses less raw material and accessories compared with compendial methods. It is also less time consuming and less prone to operator variability. Our validation approach is suitable for a validated laboratory with trained personnel capable of conducting the ATMP release tests, and with very low intra-laboratory variability, and meets the criteria required for an alternative approach to endotoxin detection for in-process and product-release testing of ATMPs.
Reference Key
pasqua2021completemolecular Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Pasqua, Salvatore;Niotta, Maria Concetta;Martino, Giuseppina Di;Sottile, Davide;Douradinha, Bruno;Miele, Monica;Timoneri, Francesca;Bella, Mariangela Di;Cuscino, Nicola;Bartolo, Chiara Di;Conaldi, Pier Giulio;D’Apolito, Danilo;
Journal molecular therapy: methods & clinical development
Year 2021
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.