A fast and validated LC-MS/MS method to quantify lenvatinib in dried blood spot.

Clicks: 54
ID: 280535
2023
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #207 of 235 articles by views in Journal of pharmaceutical and biomedical analysis

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A new LC-MS/MS method for the quantification of lenvatinib (LENVA) in venous Dried Blood Spot (DBS) samples has been presented. This method is characterized by a short run time (4 min), requires a volumetric sampling of 10 µL and extraction of the entire spot to avoid hematocrit (Hct) and spot volume effects. The quantification method was successfully validated in the range of 5.00-2000 ng/mL on two different DBS filter papers (Whatman 31 ET CHR and Whatman 903) according to European Medicines Agency (EMA) and Food and Drug Administration (FDA) guidelines, European Bioanalysis Forum (EBF), and International Association of Therapeutic Drug Monitoring and Clinical Toxicology (IATDMCT) recommendations. During the validation process, the following parameters were evaluated: recovery (≥ 77% for both filter papers), absence of matrix effect, process efficiency (close to 72% for Whatman 31 ET CHR and close to 77% for Whatman 903), Hct effect (CV ≤ 6.3% and accuracy within 96-112%), linearity (r ≥ 0.998 for Whatman 31 ET CHR and r ≥ 0.999 for Whatman 903), intra- and inter-day precision (CV ≤ 8.8%) and accuracy (92.8-108%), selectivity and sensitivity, reproducibility with incurred samples reanalysis (ISR), and stability. This method was applied to quantify venous DBS samples from patients with hepatocellular carcinoma treated with LENVA enrolled in a cross-validation study (CRO-2018-83). A good correlation between LENVA plasma concentration determined by standard procedure and the new developed DBS LENVA method (R ≥ 0.996) has been observed.
Reference Key
zanchetta2023ajournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Zanchetta, Martina;Posocco, Bianca;Gagno, Sara;Poetto, Ariana Soledad;Orleni, Marco;Canil, Giovanni;Guardascione, Michela;Puglisi, Fabio;Toffoli, Giuseppe;
Journal Journal of pharmaceutical and biomedical analysis
Year 2023
DOI
10.1016/j.jpba.2023.115255
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.