MRI Extracellular Volume Fraction in Liver Fibrosis-A Comparison of Different Time Points and Blood Pool Measurements.
Clicks: 134
ID: 278722
2024
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
134 views
49 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #10 of 13 articles by views in Journal of magnetic resonance imaging : JMRI
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Extracellular volume (ECV) correlates with the degree of liver fibrosis.To analyze the performance of liver MRI-based ECV evaluations with different blood pool measurements at different time points.Prospective.73 consecutive patients (n = 31 females, mean age 56 years) with histopathology-proven liver fibrosis.3T acquisition within 90 days of biopsy, including shortened modified look-locker inversion recovery T1 mapping.Polygonal regions of interest were manually drawn in the liver, aorta, vena cava, and in the main, left and right portal vein on four slices before and after Gd-DOTA administration at 5/10/15 minutes. ECV was calculated 1) on one single slice on portal bifurcation level, and 2) averaged over all four slices.Parameters were compared between patients with fibrosis grades F0-2 and F3-F4 with the Mann-Whitney U and fishers exact test. ROC analysis was used to assess the performance of the parameters to predict F3-4 fibrosis. A P-value <0.05 was considered statistically significant.ECV was significantly higher in F3-4 fibrosis (35.4% [33.1%-37.6%], 36.1% [34.2%-37.5%], and 37.0% [34.8%-39.2%] at 5/10/15 minutes) than in patients with F0-2 fibrosis (33.3% [30.8%-34.8%], 33.7% [31.6%-34.7%] and 34.9% [32.2%-36.0%]; AUC = 0.72-0.75). Blood pool T1 relaxation times in the aorta and vena cava were longer on the upper vs. lower slices at 5 minutes, but not at 10/15 minutes. AUC values were similar when measured on a single slice (AUC = 0.69-0.72) or based on blood pool measurements in the cava or portal vein (AUC = 0.63-0.67 and AUC = 0.65-0.70).Liver ECV is significantly higher in F3-4 fibrosis compared to F0-2 fibrosis with blood pool measurements performed in the aorta, inferior vena cava, and portal vein at 5, 10, and 15 minutes. However, a smaller variability was observed for blood pool measurements between slices at 15 minutes.1 TECHNICAL EFFICACY: Stage 3.
| Reference Key |
obmann2024mrijournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Obmann, Verena Carola;Ardoino, Marie;Klaus, Jeremias;Catucci, Damiano;Berzigotti, Annalisa;Montani, Matteo;Peters, Alan;Todorski, Inga;Wagner, Benedikt;Zbinden, Lukas;Gräni, Christoph;Ebner, Lukas;Heverhagen, Johannes Thomas;Christe, Andreas;Huber, Adrian Thomas; |
| Journal | Journal of magnetic resonance imaging : JMRI |
| Year | 2024 |
| DOI |
10.1002/jmri.29259
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.