Intravoxel incoherent motion and diffusion kurtosis imaging and their machine-learning-based texture analysis for detection and assessment of prostate cancer severity at 3 T.

Clicks: 167
ID: 278442
2024
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #8 of 9 articles by views in NMR in biomedicine

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
To evaluate the role of combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) and their machine-learning-based texture analysis for the detection and assessment of severity in prostate cancer (PCa).Eighty-eight patients underwent MRI on a 3 T scanner after giving informed consent. IVIM-DKI data were acquired using 13 b values (0-2000 s/mm) and analyzed using the IVIM-DKI model with the total variation (TV) method. PCa patients were categorized into two groups: clinically insignificant prostate cancer (CISPCa) (Gleason grade ≤ 6) and clinically significant prostate cancer (CSPCa) (Gleason grade ≥ 7). One-way analysis-of-variance, t test, and receiver operating characteristic analysis was performed to measure the discriminative ability to detect PCa using IVIM-DKI parameters. A chi-square test was used to select important texture features of apparent diffusion coefficient (ADC) and IVIM-DKI parameters. These selected texture features were used in an artificial neural network for PCa detection.ADC and diffusion coefficient (D) were significantly lower (p < 0.001), and kurtosis (k) was significantly higher (p < 0.001), in PCa as compared with benign prostatic hyperplasia (BPH) and normal peripheral zone (PZ). ADC, D, and k showed high areas under the curves (AUCs) of 0.92, 0.89, and 0.88, respectively, in PCa detection. ADC and D were significantly lower (p < 0.05) as compared with CISPCa versus CSPCa. D for detecting CSPCa was high, with an AUC of 0.63. A negative correlation of ADC and D with GS (ADC, ρ = -0.33; D, ρ = -0.35, p < 0.05) and a positive correlation of k with GS (ρ = 0.22, p < 0.05) were observed. Combined IVIM-DKI texture showed high AUC of 0.83 for classification of PCa, BPH, and normal PZ.D, f, and k computed using the IVIM-DKI model with the TV method were able to differentiate PCa from BPH and normal PZ. Texture features of combined IVIM-DKI parameters showed high accuracy and AUC in PCa detection.
Reference Key
das2024intravoxelnmr Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Das, Chandan J;Malagi, Archana Vadiraj;Sharma, Raju;Mehndiratta, Amit;Kumar, Virendra;Khan, Maroof A;Seth, Amlesh;Kaushal, Seema;Nayak, Baibaswata;Kumar, Rakesh;Gupta, Arun Kumar;
Journal NMR in biomedicine
Year 2024
DOI
10.1002/nbm.5144
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.