The effect of conformation order on gas separation properties of polyetherimide ultem films
Clicks: 32
ID: 277670
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
9.3
/100
32 views
14 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #238 of 250 articles by views in Polymers
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 250 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Changes of the spectral characteristics of absorption bands depending on the films’ treatment method were registered for polyetherimide Ultem films. The possibility of selection of structural criteria (the ratio of the functional groups absorption bands intensities) showing all conformational changes in elementary unit with metrological processing of the results is shown. It is demonstrated that film formation from chloroform solution leads to elementary unit fragments, Ph–O–Ph′, which have an effect on macromolecule conformation and result in increasing of space between fragments of macromolecules (local polymer matrix packing loosening). Desorption of residual chloroform from films by ethanol or supercritical CO2 leads to a change of conformers set in Im–Ph–Im′ units. Quantum chemical modeling showed the possibility of convergence of these fragments in neighboring macromolecules, and consequently of interchain π–π interaction (local densification of chain packing of the polymer matrix). After annealing at a temperature higher than glass transition temperature, the polyetherimide film exhibits the most disordered (amorphous) state at all of the fragments. It is demonstrated that the results, obtained by the combination of theoretical and experimental vibrational spectroscopy methods, are in good agreement with data of chain packing ordering found by analysis of gas separation parameters.
| Reference Key |
kostina2020thepolymers
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Kostina, J. |
| Journal | Polymers |
| Year | 2020 |
| DOI |
10.3390/polym12071578
|
| URL | |
| Keywords | Keywords not found |