Comparing accuracy of cochlear measurements on magnetic resonance imaging and computed tomography: A step towards radiation-free cochlear implantation.

Clicks: 127
ID: 277568
2023
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #4 of 4 articles by views in Journal of otology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) are commonly employed in pre-operative evaluation for cochlear implant surgery. However, with a decrease in the age of implantation, even minor radiation exposure can cause detrimental effects on children over their lifetime. The current study compares different cochlear measurements from CT and MRI scans and evaluates the feasibility of using only an MRI scan for radiological evaluation before cochlear implantation.A longitudinal observational study was conducted on 94 ears/47 children, employing CT and MRI scans. The CT and MRI scan measurements include, A value, B value, Cochlear duct length (CDL), two-turn cochlear length, alpha and beta angles to look for cochlear orientation. Cochlear nerve diameter was measured using MRI. The values were compared.The mean difference between measurements from CT and MRI scans for A value, B value, CDL, and two-turn cochlear length values was 0.567 ± 0.413 mm, 0.406 ± 0.368 mm, 2.365 ± 1.675 mm, and 2.063 ± 1.477 mm respectively without any significant difference. The alpha and beta angle measures were comparable, with no statistically significant difference.The study suggests that MRI scans can be the only radiological investigation needed with no radiation risk and reduces the cost of cochlear implant program in the paediatric population. There is no significant difference between the measurements obtained from CT and MRI scans. However, observed discrepancies in cochlear measurements across different populations require regionally or race-specific standardized values to ensure accurate diagnosis and precision in cochlear implant surgery. This aspect must be addressed to ensure positive outcomes for patients.
Reference Key
swarup2023comparingjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Swarup, Anurita;Karakkandy, Vinusree;Chappity, Preetam;Naik, Suprava;Behera, Sanjay Kumar;Parida, Pradipta Kumar;Grover, Mohnish;Gupta, Gaurav;Giri, Prajna Paramita;Sarkar, Saurav;Pradhan, Pradeep;Samal, Dillip Kumar;Kallyadan Veetil, Aswathi;Adhikari, Asutosh;Nayak, Saurav;
Journal Journal of otology
Year 2023
DOI
10.1016/j.joto.2023.08.001
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.