Damage Detection and Evaluation for an In-Service Shield Tunnel Based on the Monitored Increment of Neutral Axis Depth Using Long-Gauge Fiber Bragg Grating Sensors.

Clicks: 186
ID: 27744
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #1,396 of 1,694 articles by views in sensors

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,694 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
It is difficult to detect and evaluate the structural damage in a shield tunnel during operation because many traditional techniques based on the observation of vibrations are limited in daily monitoring in tunnels. Thus, the curvature radius of a static longitudinal settlement curve is used to identify the residual health and safety of an in-service shield tunnel. However, there are still two problems. The curvature radius is suitable for a qualitative judgment rather than a quantitative evaluation for longitudinal damage detection. Moreover, the curvature radius, which is calculated from the measured settlements of three neighboring points, gives an average damage degree in a wide scope only and is difficult to use to identify the damage's precise location. By means of the analysis of three kinds of longitudinal failure modes in a shield tunnel, this paper proposes: (1) a damage detection method based on the monitored increment of the neutral axis depth; and (2) an index to evaluate longitudinal damage. The index is composed of the residual ratios of the equivalent flexural stiffness (HFM1) and the equivalent shear stiffness (HFM3). The neutral axis position and the proposed damage index can be determined using long-gauge Fiber Bragg Grating sensors. Results from numerical simulations show that the deviation between the HFM1 and the true value residual ratio of the equivalent flexural stiffness is no more than 1.7%. The HFM3 is equal to its true value in the entire damage process. A loading experiment for a scaled-down model of a shield tunnel using long-gauge Fiber Bragg Grating sensors indicated that the errors in the HFM1 were no more than 5.0% in the case of early damage development (HFM1 ≥ 0.5). The maximum error did not exceed 9.0% even under severe damage conditions in the model. Meanwhile, the HFM3 also coincided with its true value in the entire testing process.
Reference Key
shen2019damagesensors Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Shen, Sheng;Lv, Huaxin;Ma, Sheng-Lan;
Journal sensors
Year 2019
DOI
E1840
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.