Creating consistency in the diagnosis of convergence insufficiency: screening methods.
Clicks: 93
ID: 277401
2023
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
27.6
/100
93 views
32 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #4 of 4 articles by views in Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
To determine the sensitivity of various clinical tests in the diagnosis of convergence insufficiency.A total of 254 patients were recruited with complaints consistent with convergence problems but no prior history of strabismus surgery, eye exercises, prism use, recent concussion, or other ocular or neurological diseases. Each patient completed the convergence insufficiency symptom survey (CISS), and the following data were collected: ocular alignment at distance and near, convergence and divergence fusional amplitudes at distance and near, near-point of convergence (NPC) using an accommodative target and red lens, and assessment of quality of convergence movement (QoCM) and quality of fusional movements (QoFM). The sensitivity of each clinical test was calculated.Measurement of NPC using red lens and subjective assessment of the QoCM and QoFM were the most sensitive diagnostic tools for near symptoms consistent with convergence insufficiency: 93.3%, 98.4%, and 94.5% respectively. CISS score, convergence fusional amplitude at near, and exophoria at near had lower sensitivities: 62.9%, 46.0%, and 72.0%, respectively. Although the majority of our patients had a heterophoria or heterotropia at distance (96.8%) and/or near (98.8%), most presented with only small phorias. Furthermore, of those who had a deviation at near, only 22% had the near exophoria exceeding the distance exophoria by 10.In our study cohort, NPC with red lens and subjective assessment of QoCM and QoFM proved to be the most sensitive screening tools for near symptoms consistent with convergence insufficiency.
| Reference Key |
lavrich2023creatingjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Lavrich, Judith B;Hamburger, Jordan L;Lee, Karen E;Thuma, Tobin B T;Omega, Michelle L;Zhang, Qiang Ed;Gunton, Kammi B; |
| Journal | Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus |
| Year | 2023 |
| DOI |
S1091-8531(23)00234-3
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.