Development of a high throughput human stool specimen processing method for a molecular Helicobacter pylori clarithromycin resistance assay.

Clicks: 88
ID: 276644
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #1,984 of 2,056 articles by views in PloS one

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 2,056 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
It has become critical to detect Helicobacter pylori (H. pylori) infection due to the link to gastric cancer with some strains. These strains are also increasing in resistance to antibiotics with clarithromycin leading the way as the first line treatment. Resistance to clarithromycin has been shown to correlate with the A2142G, A2142C, and A2143G mutations on the rrl gene. In the last few decades, non-invasive specimens, such as stool, have been a reliable alternate to gastric biopsy for immunoassay tests. More recently, it has been proven feasible for stool to be used in molecular based tests. Many of the core laboratories in the United States need a high throughput sample preparation to run this test. Here, a high throughput assay is compared to a previously published manual sample prep H. pylori molecular based assay. Using the Magna Pure 96 (Roche), at least 96 stool species and 96 biopsy specimens can be tested in an 8-hour shift of a clinical lab. The high throughput sample prep had a positive percent agreement (PPA) of 87% compared to the manual sample prep using the same testing configuration. The genotype predictions from the high throughput assay matched genotype predictions from the manual sample prep with the same stool sample 92% of the time. A concordance rate of 89% was observed with genotype predictions from the high throughput assay of the same patient stool and biopsy. In stool samples from the high throughput assay, there was 100% concordance between the quantitative polymerase chain reaction (qPCR)-derived genomic prediction and DNA sequencing data. The high throughput workflow can get more patients tested faster in addition to detection of mutations associated with clarithromycin resistance.
Reference Key
clines2019developmentplos Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Clines, Natalie;Beckman, Erin;
Journal PloS one
Year 2019
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.